Adopting the constant current method to apply automated testing system
Perfect feature for the Production line which requires re- duced tact timeThe TOS6200A is designed to perform the ground bond tests required for class-I devices by safety standards such as IEC, EN, VDE, BS, UL, JIS, and the Electrical Appliance and Material Safety Low (Japan). Equipped with a new high-efficiency power supply, it is compact and lightweight, about half the size and weight of our conventional prod- ucts, while achieving a large output of 150 VA. Use of the constant current method eliminates the need to reset test currents even in the face of fluctuating resistance values for the device being tested. The test duration can also be set from 0.3 s, making the tester suitable for production line testing, which requires reduced cycle time. This tester is also designed for ease of use, featuring a large, easy-to-read display, memory capacity for storage of 100 types of test conditions, and incorporation of test conditions into programs to enable automatic testing. The standard equipped GPIB and RS232C interfaces allow the user to use PCs or other devices to control test conditions such as test current, resistance value for judgement, and test duration, and en- ables read-back of measured values and test results.
- Test current value: 3 A to 30 A AC / Resistance value: 0.001 Ω to 1.200 Ω
- Offset cancelling function
- Stores 100 test conditions in memory
- Incorporates test conditions into program
- Contact check function
- Equipped with standard GPIB and RS232C interfaces
Adopting the constant current method to apply automated testing system
Perfect feature for the Production line which requires re- duced tact timeThe TOS6200A is designed to perform the ground bond tests required for class-I devices by safety standards such as IEC, EN, VDE, BS, UL, JIS, and the Electrical Appliance and Material Safety Low (Japan). Equipped with a new high-efficiency power supply, it is compact and lightweight, about half the size and weight of our conventional prod- ucts, while achieving a large output of 150 VA. Use of the constant current method eliminates the need to reset test currents even in the face of fluctuating resistance values for the device being tested. The test duration can also be set from 0.3 s, making the tester suitable for production line testing, which requires reduced cycle time. This tester is also designed for ease of use, featuring a large, easy-to-read display, memory capacity for storage of 100 types of test conditions, and incorporation of test conditions into programs to enable automatic testing. The standard equipped GPIB and RS232C interfaces allow the user to use PCs or other devices to control test conditions such as test current, resistance value for judgement, and test duration, and en- ables read-back of measured values and test results.
- Test current value: 3 A to 30 A AC / Resistance value: 0.001 Ω to 1.200 Ω
- Offset cancelling function
- Stores 100 test conditions in memory
- Incorporates test conditions into program
- Contact check function
- Equipped with standard GPIB and RS232C interfaces
AC power cord | 1 piece |
Test leadwire TL11-TOS | 1 set |
Short bar | 2 pieces (These are inserted between the OUTPUT and SAMPLING terminals.) |
AC power fuse | 2 pieces (2, including one spare in the fuse holder) |
Operation manual | 1 copy |
AC power cord | 1 piece |
Test leadwire TL11-TOS | 1 set |
Short bar | 2 pieces (These are inserted between the OUTPUT and SAMPLING terminals.) |
AC power fuse | 2 pieces (2, including one spare in the fuse holder) |
Operation manual | 1 copy |
TOS6200A | ||
Ground Bond Tester | ||
Output block | ||
Current setting range (*1) | 3.0 Aac to 31.0 Aac (With respect to resistance resulting in output power of the maximum rated Output or less and an output terminal voltage of 5.4 V or less) | |
Resolution | 0.1 A | |
Accuracy | ± (1% of setting + 0.2 A) | |
Maximum rated output | 150 VA (at the output terminals) | |
Distortion factor | 2% or less (with respect to 0.1 Ω pure resistance load of 10 A or greater) | |
Frequency | 50/60 Hz, sine wave (selectable) | |
Accuracy | ±200 ppm | |
Open terminal voltage | 6 Vrms or less | |
Output method | PWM switching method | |
Output ammeter | ||
Measurement range | 0.0 Aac to 33.0 Aac | |
Resolution | 0.1 A | |
Accuracy | ± (1% of reading + 0.2 A) | |
Response | Mean value response/rms value display (response time: 200 ms) | |
Holding function | The current measured at the end of test is held during the PASS or FAIL inteval | |
Output voltmeter | ||
Measurement range | 0.00 Vac to 6.00 Vac | |
Resolution | 0.01 V | |
Accuracy | ± (1% of reading + 0.02 V) | |
Response | Mean value response/rms value display (response time: 200 ms) | |
Holding function | The voltage measured at the end of test is held during the PASS or FAIL inteval | |
Ohmmeter (*2) | ||
Measurement range | 0.001 Ω to 1.200 Ω | |
Resolution | 0.001 Ω | |
Offset cancel function | 0.000 Ω to 1.200 Ω (Offset ON/OFF function provided) | |
Accuracy | ± (2% of reading + 0.003 Ω) | |
Holding function | The resistance measured at the end of test is held during the PASS interval | |
Pass/fail judgement function | ||
Resistance value-based judgement | Window comparator system •If a resistance value equal to or greater than the upper reference value is detected,a FAILdetermination is returned. •If a resistance value equal to or less than the lower reference value is detected, a FAIL determination is returned. •If a resistance value has been judged as FAIL, the tester shuts off the output and generates a FAIL signal. •If the set time elapses without abnormalities, the tester shuts off the output and generates a PASS signal. | |
Setting range for the upper rerence value (UPPER) | 0.001 Ω to 1.200 Ω | |
Setting range for the upper rerence value (LOWER) | 0.001 Ω to 1.200 Ω | |
Resolution | 0.001 Ω | |
Judgement accuracy | ± (2% of UPPER + 0.003 Ω) | |
Calibration | Calibration is performed with the rms value of the sine wave, using a pure resistance load. | |
LED | PASS | Lights for approximately 0.2 sec when the measured value has been judged as PASS.It is lit continuously when the PASS holding time is set to HOLD. |
UPPER FAIL | Lights if a resistance value equal to or greater than the upper reference value is detected and judged FAIL. | |
LOWER FAIL | Lights if a resistance value equal to or greater than the upper reference value is detected and judged FAIL. | |
Buzzer | •The buzzer sounds for the pass holding time has been set if the measured value has been judged as PASS. •The buzzer sounds continuously under the following condition: The measured value has been judged as PASS when the PASS holding time is set to HOLD. The measured value has been judged as UPPER FAIL. The measured value has been judged as LOWER FAIL. •The buzzer volume for FAIL or PASS judgment are adjustable. Note that it cannot be adjusted individually since setting is shared with the setting for PASS. | |
Time | ||
Test Time | Setting range | 0.3 s to 999 s Timer ON/OFF function is available. |
Accuracy | ± (100ppm of setting + 20ms) | |
Environment | ||
Operating environment | Indoor use, Overvoltage Category II | |
Warranty range | Temperature : 5°C to 35°C Humidity : 20 %rh to 80 %rh (non condensing) | |
Operating range | Temperature : 0°C to 40°C Humidity : 20 %rh to 80 %rh (non condensing) | |
Storage range | Temperature : -20°C to 70°C Humidity : 90 %rh or less (non condensing) | |
Altitude | Up to 2000 m | |
Power requirement | ||
Allowable voltage range | 85 Vac to 250 Vac | |
Power consumption | At no load (READY) | 60 VA or less |
At rated load | 280 VA max. | |
Allowable frequency range | 47 Hz to 63 Hz | |
Insulation resistance | 30 MΩ min. (500 Vdc), between AC line and chassis | |
Withstanding voltage | 1390 Vac (2 seconds), between AC line and chassis | |
Earth continuity | 25 Aac/ 0.1 Ω max. | |
Safety (*3) Conforms to the requirements of the following directive and standard. | ||
Low Voltage Directive 2014/35/EU, EN 61010-1 (Class I, Pollution degree 2) | ||
Electromagnetic compatibility (EMC) (*3,4) | ||
Conforms to the requirements of the following directive and standard. EMC Directive 2014/30/EU, EN 61326-1 (Class A), EN 55011 (Class A, Group 1), EN 61000-3-2, EN 61000-3-3 Under following conditions 1. | Used test leadwire (TL11-TOS for TOS6200A, TL12-TOS for TOS6210) which is supplied. 2. | Used the shielded cable which length is less than three meters when the SIGNAL I/O is used. |
Physical dimensions (maximum) | 430[16.93 inch] (455[17.91 inch]) W × 88[3.46 inch] (140[5.51 inch]) H × 270[10.63 inch] (345[13.58 inch]) D mm | |
Weight | Approx. 9 kg (Approx.19.84 lbs) | |
Accessories | ||
AC power cord | 1 piece | |
Test leadwire TL11-TOS | 1 set | |
Short bar | 2 pieces (These are inserted between the OUTPUT and SAMPLING terminals.) | |
AC power fuse | 2 pieces (2, including one spare in the fuse holder) | |
Operation manual | 1 copy |
Товар |
|
|
Модели и Опции |
Описание |
Цена | Заказать |
0
Модели |
TOS6200A
|
Тестер заземления 0.001 Ом - 1.200 Ом, 0 A - 30 A
|
По запросу |
1
Аксессуары |
RC01-TOS
|
Пульт дистанционнного управления одной рукой для серии TOS
|
По запросу | ||
RC02-TOS
|
Пульт дистанционнного управления двумя руками для серии TOS
|
По запросу | ||
DD-3 5P
|
DIN кабель, длина:3 м
|
По запросу | ||
LP01-TOS
|
Тестовый пробник для TOS6200, длина кабеля: 2 м, макс. 30 A
|
По запросу | ||
LP02-TOS
|
Тестовый пробник для TOS6210, длина кабеля: 2 м, макс. 60 A
|
По запросу | ||
TL11-TOS
|
Низковольтный тестовый щуп TOS6200(макс. 30 A / длина: 1.5 м)
|
По запросу | ||
TL12-TOS
|
Низковольтный тестовый щуп TOS6210(макс. 60 A / длина: 1.5 м)
|
По запросу |